MSD Ignition Modul/skrzynka zaplonowa
123 wyniki
MSD6425
Skrzynka zaplonowa Cyfrowa
* High Output w/530 Volts And 135Mj Of Spark Energy * Efficient components use less current to produce more power * Set An Rpm Limit w/Two Rotary Dials In 100 Rpm Increments * Built-in LED for syst ...Pokaż więcej
* High Output w/530 Volts And 135Mj Of Spark Energy
* Efficient components use less current to produce more power* Set An Rpm Limit w/Two Rotary Dials In 100 Rpm Increments* Built-in LED for system checks* All wires exit through a locked; sealed connector* Compatible w/4/6/8 Cylinder EnginesMSD6560
Skrzynka zaplonowa
* MSDs Popular 6M-2 w/Built-In Rev-Limiter * Multiple sparks improve starting/throttle response/idle quality * Circuitry is potted for a weather-proof housing * Weathertight connectors protect wiri ...Pokaż więcej
* MSDs Popular 6M-2 w/Built-In Rev-Limiter
* Multiple sparks improve starting/throttle response/idle quality* Circuitry is potted for a weather-proof housing* Weathertight connectors protect wiring from water and chemicalsMSD6201
Skrzynka zaplonowa Cyfrowa
* Will not accept a rev limiter * High Output w/530 Volts And 135Mj Of Spark Energy * Efficient components use less current to produce more power * Built-in LED for system checks * All wires exit ...Pokaż więcej
* Will not accept a rev limiter
* High Output w/530 Volts And 135Mj Of Spark Energy* Efficient components use less current to produce more power* Built-in LED for system checks* All wires exit through a locked; sealed connector* Compatible w/4/6/8 Cylinder EnginesMSD6423
Skrzynka zaplonowa Cyfrowa
High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with ...Pokaż więcej
High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with less current draw)
High RPM operation and maximum output using the Blaster HVC, PN 8252 or HVC II, PN 8253Powerful capacitive discharge of multiple sparks improves performanceConsistently high spark energy of 135mJ to 150mJ for every firing, from idle to redline RPMIncrease spark series duration lasts for 18 of crankshaft rotationEasily installs on 4, 6, 8-cylinder engines with distributorsOperates on most 7 to 28 volt electrical systemsConnects to points, magnetic pickups, and Hall/Crank Input distributorsBluetooth connectivity to Mobile app interface for settings and monitorsMSD CAN communication for easy connectivity to MSDView using a CAN MSD Hub and Power Grid USB or CAN-USB Bridge 89982 productFully protected against an open coil, shorted coil & open loadCompact design full MSD powerQuickens throttle response & improves startingTach OutputLaunch, Burnout, and Step Retard activation inputs available. This ignition box has a built-in tri step RPM rev limit controlled by the mobile appMobile app available settings: Cylinder selection, Step retard value, Launch RPM value, Burnout RPM value, Max (Race) RPM Value, Start retard valueProgrammable Step Retard: On Ramp time, Off Delay, Off Ramp Time, Engine RPM for activationProgrammable Start Retard: 0, 10, 20 degreesAlerts and monitors availableHigh level of security connection from phone to Ignition box (encryption) including sequence in push button implementationMaximum programmable retard of 30 degreesMSD64233
Skrzynka zaplonowa Cyfrowa
High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with ...Pokaż więcej
High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with less current draw)
High RPM operation and maximum output using the Blaster HVC, PN 8252 or HVC II, PN 8253Powerful capacitive discharge of multiple sparks improves performanceConsistently high spark energy of 135mJ to 150mJ for every firing, from idle to redline RPMIncrease spark series duration lasts for 18 of crankshaft rotationEasily installs on 4, 6, 8-cylinder engines with distributorsOperates on most 7 to 28 volt electrical systemsConnects to points, magnetic pickups, and Hall/Crank Input distributorsBluetooth connectivity to Mobile app interface for settings and monitorsMSD CAN communication for easy connectivity to MSDView using a CAN MSD Hub and Power Grid USB or CAN-USB Bridge 89982 productFully protected against an open coil, shorted coil & open loadCompact design full MSD powerQuickens throttle response & improves startingTach OutputLaunch, Burnout, and Step Retard activation inputs available. This ignition box has a built-in tri step RPM rev limit controlled by the mobile appMobile app available settings: Cylinder selection, Step retard value, Launch RPM value, Burnout RPM value, Max (Race) RPM Value, Start retard valueProgrammable Step Retard: On Ramp time, Off Delay, Off Ramp Time, Engine RPM for activationProgrammable Start Retard: 0, 10, 20 degreesAlerts and monitors availableHigh level of security connection from phone to Ignition box (encryption) including sequence in push button implementationMaximum programmable retard of 30 degreesMSD65233
Skrzynka zaplonowa
High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with ...Pokaż więcej
High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with less current draw)
High RPM operation and maximum output using the Blaster HVC, PN 8252 or HVC II, PN 8253Powerful capacitive discharge of multiple sparks improves performanceConsistently high spark energy of 135mJ to 150mJ for every firing, from idle to redline RPMIncrease spark series duration lasts for 18 of crankshaft rotationEasily installs on 4, 6, 8-cylinder engines with distributorsOperates on most 7 to 28 volt electrical systemsConnects to points, magnetic pickups, and Hall/Crank Input distributorsBluetooth connectivity to Mobile app interface for settings and monitorsMSD CAN communication for easy connectivity to MSDView using a CAN MSD Hub and Power Grid USB or CAN-USB Bridge 89982 productStraight USB port to easily connect to MSDView using a laptopFully protected against an open coil, shorted coil & open loadCompact design full MSD powerQuickens throttle response & improves startingTach OutputLaunch, Burnout, and Step Retard activation inputs available. This ignition box has a built-in tri step RPM rev limit controlled by the mobile appMobile app available settings: Step retard value, Launch RPM value, Burnout RPM value, Max (Race) RPM ValueProgrammable Step Retard: On Ramp time, Off Delay, Off Ramp Time, Engine RPM for activationProgrammable Start Retard through rotary switches: 0, 10, 20 degreesProgrammable cylinder selection through rotary switches: 4, 6, and 8 cylindersAlerts and monitors availableHigh level of security connection from phone to Ignition box (encryption) including sequence in push button implementationMaximum programmable retard of 35 degreesProgrammable timing curves in 2D Plots or 3D tables (RPM vs Timing vs MAP Pressure) - You can plot the 3D graph and edit a table 20x20 either from Mobile app (Phone) or from MSDView (laptop)Programmable Launch Timing (Seconds vs degrees after launch wire activation)MAP sensor interface up to 400 kPA (58 PSI / 4 Bars)Capable to program cylinder selection and start retard without a computer or app for old school racers (like 6425 or 6428 box)MSD5520
Skrzynka zaplonowa Cyfrowa
* Capacitive Discharge Technology * Multiple Sparks Improve Starting And Idle * Full Power Output At High RPM * Connects to points/amplifiers/magnetic pickup distributors * Adjustable rev limiter ...Pokaż więcej
* Capacitive Discharge Technology
* Multiple Sparks Improve Starting And Idle* Full Power Output At High RPM* Connects to points/amplifiers/magnetic pickup distributors* Adjustable rev limiter for overrev protectionMSD5596
HEI MODULE - STREET FIRE
* Replace The OEM Ignition Module w/Street Fire * Module Replaces OEM GM HEI And Street Fire Dist. * Fits Street Fire Dist. PN[8362] And OEM * Perfect For Budget Minded Enthusiasts
* Replace The OEM Ignition Module w/Street Fire
* Module Replaces OEM GM HEI And Street Fire Dist.* Fits Street Fire Dist. PN[8362] And OEM* Perfect For Budget Minded EnthusiastsMSD6421
Skrzynka zaplonowa
* All new housing; same reliable digital circuitry and performance * Built-In 2-Step Rev Control Adjustable w/Rotary Dials * Higher Output w/Up To 135Mj Of Spark Energy * Accepts Hall-effect; point ...Pokaż więcej
* All new housing; same reliable digital circuitry and performance
* Built-In 2-Step Rev Control Adjustable w/Rotary Dials* Higher Output w/Up To 135Mj Of Spark Energy* Accepts Hall-effect; points and mag pickup triggers* Managed by an efficient digital processorMSD6462
Skrzynka zaplonowa
* Multiple spark; capacitive discharge ignition control * Multiple Sparks For 20 deg. of Crankshaft Rotation * Retards ignition timing 1-3 deg per/lb. of boost (max. 15 deg.) * Dash mounted adjusta ...Pokaż więcej
* Multiple spark; capacitive discharge ignition control
* Multiple Sparks For 20 deg. of Crankshaft Rotation* Retards ignition timing 1-3 deg per/lb. of boost (max. 15 deg.)* Dash mounted adjustable control knob* Supplied w/3000/6000/7000/8000 Amp Rpm Modules* Supplied w/Rubber Shock Mounts* Programmable for 4/6/8 cyl. by cutting red/blue wire loops* Built-In Soft Touch Rev Control Is Adjustable w/Rpm Modules* 110 Millijoules Per Spark Up To 15000 RPM* 470 Primary Voltage Output To Coil* Accepts breaker points/amplifier/magnetic pickup trigger inputs* Works on 12-18 volt electrical systemMSD6520
Skrzynka zaplonowa
* Switch between 2 rev limits * Single stage retard for nitrous and top end performance. * Start retard eases pressure on the starter; flywheel and engine. * Adj. magnetic pickup compensation for a ...Pokaż więcej
* Switch between 2 rev limits
* Single stage retard for nitrous and top end performance.* Start retard eases pressure on the starter; flywheel and engine.* Adj. magnetic pickup compensation for accurate trigger signals.* LED warns of trigger signal problems or faulty charging system.MSD6530
Skrzynka zaplonowa
* Advanced features allow for use in street and racing applications * PC Programmable w/Easy-to-use Windows based Pro-Data +Software * Plot A Boost Timing Map w/0.1 Deg. Per Psi Accuracy * Programm ...Pokaż więcej
* Advanced features allow for use in street and racing applications
* PC Programmable w/Easy-to-use Windows based Pro-Data +Software* Plot A Boost Timing Map w/0.1 Deg. Per Psi Accuracy* Programmable 3-Step Rev Limiter (100 RPM increments)* Step retard for nitrous applications plus a boost timing map* Capacitive Discharge tech. for fast rise time/max. spark energyMSD8743
Chip RPM 3000 Serien
* Five Modules Provided * 200 RPM Increments; Even * From 3000-3800 RPM
* Five Modules Provided
* 200 RPM Increments; Even* From 3000-3800 RPMMSD8746
Chip RPM 6000 Serien
* Five Modules Provided * 200 RPM Increments; Even * From 6000-6800 RPM
* Five Modules Provided
* 200 RPM Increments; Even* From 6000-6800 RPMMSD83647
Modul zaplonu
* Easily installs to non-computer controlled (4-Pin) HEI housings * Built-in adjustable rev limiter can easily be set externally * Advanced dwell control for improved high rpm output * The Hottest ...Pokaż więcej
* Easily installs to non-computer controlled (4-Pin) HEI housings
* Built-in adjustable rev limiter can easily be set externally* Advanced dwell control for improved high rpm output* The Hottest HEI Module you buy-period!* Produces an incredible 8.5 amps of juice* Adjust The Rev Limiter w/o Removing The Cap* Fits in stock HEI distributorsMSD87441
Chip RPM 4000 Serien
* Five Modules Provided * 200 RPM Increments; Odd * From 4100-4900 RPM
* Five Modules Provided
* 200 RPM Increments; Odd* From 4100-4900 RPMMSD7751
Launch Controll Module, Power Grid
* Make Last Minute Changes * Change Shift Light And RPM Launch
* Make Last Minute Changes
* Change Shift Light And RPM LaunchMSD7761
ARC Module, Power Grid
* Plugs Into CAN-BUS Bridge * For Use w/Power Grid Controller * 4-Connector CAN-Bus Hub required
* Plugs Into CAN-BUS Bridge
* For Use w/Power Grid Controller* 4-Connector CAN-Bus Hub requiredMSD8750
Module Kit, 9000 Series
* Five Modules Provided * 200 RPM Increments; Even * From 10000-10800 RPM
* Five Modules Provided
* 200 RPM Increments; Even* From 10000-10800 RPMMSD8751
Module Kit, 9000 Series
* Five Modules Provided * 200 RPM Increments; Even * From 11000-11800 RPM
* Five Modules Provided
* 200 RPM Increments; Even* From 11000-11800 RPMMSD8677
Adjustable RPM Module
* Simple Adjustable Low RPM Module * Dial In Any RPM Range Between 1K And 3K * Change RPM By Turning A Potentiometer * Great w/Auto Tranny Using MSD 2 Step Mod Selector
* Simple Adjustable Low RPM Module
* Dial In Any RPM Range Between 1K And 3K* Change RPM By Turning A Potentiometer* Great w/Auto Tranny Using MSD 2 Step Mod SelectorMSD8748
Chip RPM 8000 Serien
* Five Modules Provided * 200 RPM Increments; Even * From 8000-8800 RPM
* Five Modules Provided
* 200 RPM Increments; Even* From 8000-8800 RPMMSD87431
Chip RPM 3000 Serien
* Five Modules Provided * 200 RPM Increments; Odd * From 3100-3900 RPM
* Five Modules Provided
* 200 RPM Increments; Odd* From 3100-3900 RPMMSD6523
Skrzynka zaplonowa
High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with ...Pokaż więcej
High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with less current draw)
High RPM operation and maximum output using the Blaster HVC, PN 8252 or HVC II, PN 8253Powerful capacitive discharge of multiple sparks improves performanceConsistently high spark energy of 135mJ to 150mJ for every firing, from idle to redline RPMIncrease spark series duration lasts for 18 of crankshaft rotationEasily installs on 4, 6, 8-cylinder engines with distributorsOperates on most 7 to 28 volt electrical systemsConnects to points, magnetic pickups, and Hall/Crank Input distributorsBluetooth connectivity to Mobile app interface for settings and monitorsMSD CAN communication for easy connectivity to MSDView using a CAN MSD Hub and Power Grid USB or CAN-USB Bridge 89982 productStraight USB port to easily connect to MSDView using a laptopFully protected against an open coil, shorted coil & open loadCompact design full MSD powerQuickens throttle response & improves startingTach OutputLaunch, Burnout, and Step Retard activation inputs available. This ignition box has a built-in tri step RPM rev limit controlled by the mobile appMobile app available settings: Step retard value, Launch RPM value, Burnout RPM value, Max (Race) RPM ValueProgrammable Step Retard: On Ramp time, Off Delay, Off Ramp Time, Engine RPM for activationProgrammable Start Retard through rotary switches: 0, 10, 20 degreesProgrammable cylinder selection through rotary switches: 4, 6, and 8 cylindersAlerts and monitors availableHigh level of security connection from phone to Ignition box (encryption) including sequence in push button implementationMaximum programmable retard of 35 degreesProgrammable timing curves in 2D Plots or 3D tables (RPM vs Timing vs MAP Pressure) - You can plot the 3D graph and edit a table 20x20 either from Mobile app (Phone) or from MSDView (laptop)Programmable Launch Timing (Seconds vs degrees after launch wire activation)MAP sensor interface up to 400 kPA (58 PSI / 4 Bars)Capable to program cylinder selection and start retard without a computer or app for old school racers (like 6425 or 6428 box)MSD2762
Atomic Trans Controller, Handheld Only
* Replacement Handheld For The Transmission * Control Module * Easy To View Parameters * Lcd Contrast Adjustment * Backlight Level Adjustment
* Replacement Handheld For The Transmission
* Control Module* Easy To View Parameters* Lcd Contrast Adjustment* Backlight Level AdjustmentMSD4224
Skrzynka zaplonowa
* Adjustable Timing Controls * Adjustable Individual Cylinder Timing * Adjustable Timed Launch Retard * Adjustable Retards * Adjustable Boost Retard Curve * Adjustable Shift Programs
* Adjustable Timing Controls
* Adjustable Individual Cylinder Timing* Adjustable Timed Launch Retard* Adjustable Retards* Adjustable Boost Retard Curve* Adjustable Shift ProgramsMSD4244
Skrzynka zaplonowa
* Direct Plug In * Instant MPH Increases * 10 Timing/Fuel Maps * Laptop Programmable * Built In Chaperone Setting
* Direct Plug In
* Instant MPH Increases* 10 Timing/Fuel Maps* Laptop Programmable* Built In Chaperone Setting